Transformer Winding Resistance Test With Epoxy Bushing
Transformer is one of the most important equipment in the power system, carrying the heavy responsibility of power transmission. In its daily operatio ...
Technical Overview Of 10kv Indoor Insulated Contact Box
3.1 Function and Use of Insulation Contact Box The 10kv indoor contact box is a widely used device in the power system, which is used to connect and i ...
Integrated Sealed Pole
The integrated Embedded Pole is a key component widely used in high-voltage electrical equipment. Its main function is to achieve a close combination ...
Characteristics Of High Voltage Epoxy Resin Insulators
High voltage high voltage standoff insulators has the following notable features: 1. Excellent insulation performance Epoxy resin has good insulation ...
Functions And Requirements Of Transformer Epoxy Bushing
Transformer epoxy resin bushing is one of the current-carrying components. epoxy bushing for transformer leads the high and low voltage leads inside t ...
10kv Indoor Insulation Contact Box Technical Standard Explanation And Overview
1. Introduction 1.1 Overview This article aims to explain and illustrate the 10kv indoor Insulation Contact Box technical standard in detail and give ...
Advantages Of Solid-sealed Poles
Miniaturized equipment The use of Embedded Pole can reduce the phase spacing of the circuit breaker, thereby further miniaturizing the circuit breaker ...
High Voltage Standoff Insulators
Introduction high voltage standoff insulators is an important electrical equipment used in power transmission and distribution systems. It has excelle ...
Epoxy Bushing Pressure Test
epoxy bushing is a bushing used for insulation of electrical equipment. To ensure its insulation performance, a withstand voltage test is required. He ...
Countermeasures For Heating Of Switch Cabinet Contacts
1. Correctly measure the circuit resistance of the switch cabinet Since the heating failure of the switch cabinet equipment is mostly caused by poor I ...
What Is Embedded Pole?
What is Embedded Pole? Using APG casting process The so-called solid-sealed pole refers to the use of advanced APG casting process, through a special ...
High Voltage Standoff Insulators Casting Process
At present, with the rapid development of the power industry, one of the pillar industries in my country, the equipment of the power generation indust ...
Epoxy Resin Casing Test Report
1. Background Introduction With the development and update of the power system, epoxy bushing plays an important role in power equipment, power transm ...
Analysis Of The Causes Of Heating Of 10kv Insulating Contact Box And Its Countermeasures
Abstract: As an important equipment of the power supply and distribution system, the circuit breaker is responsible for the conversion and transmissio ...
Embedded Pole Production Process
Introduction In the medium voltage field, especially at the 12kV voltage level, vacuum circuit breakers have become mainstream products. The pole insu ...
Acceptance Rules For High Voltage Insulators
1) Before the product is shipped, the buyer shall send inspection personnel to the supplier for random inspection and acceptance. 2) The supplier shal ...
Ac Withstand Voltage Test Steps For Insulators And Bushings
1) Discharge the test object to ground and remove the lead wire. (2) Wipe the dirt on the outer insulation surface of the test object with a clean, so ...
Analysis Of Low Insulation Problem Of Busbar In 35kv Switch Cabinet
After the purchase of Insulation Contact Box, the technicians carried out a power outage inspection and treatment of the low insulation problem of the ...
Solid-sealed Pole Single-pole Assembly
Embedded Pole is an assembly of vacuum interrupter and upper and lower outlet seats and other parts. During assembly, it is necessary to ensure that t ...
Technical Information That High Voltage Insulators Should Provide
1) High Voltage Insulator Assembly drawings that can explain the installation dimensions and umbrella type and the dimension drawings of each section. ...
Insulator And Bushing Ac Withstand Voltage Test Principle Wiring
(1) When the Switchgear Insulating Bushing main insulation withstands voltage, the primary side of the bushing is connected to the high voltage part o ...
Insulation Testing After Replacing The Insulating Contact Box
Insulation Contact Box The three-phase busbar was tested again with the insulation resistance tester at the same gear. Phase A: 377GΩ, Phase B: 3.2GΩ, ...
Solid-sealed Pole Cleaning
Embedded Pole The upper outlet seat, lower outlet seat, inserts and other parts that need to be embedded in epoxy resin should be cleaned with alcohol ...